Secolink Intruder alarm panel PAS series
Secolink Intruder alarm panel PAS series control panels perform all necessary functions to protect all types offices, homes or villas. Additional features of this series are especially highlighted in countries where landlines are still popular. During an alarm PAS panels can call user’s phone through a built-in telephone communicator and vocally report about the nature of an alarm. All models protect four partitions and depending on the panel being used it can have up to 8, 16, or 32 zones in the alarm system and can be controlled by 5 or 31 users.
For alarm monitoring companies are designed SECOLINK RCR and SECOLINK IP2 receivers. Devices receive information from the GSV4, GSV5, GSV6U, GSVU, VIDNET, LAN800 internet communicators. SECOLINK RCR receiver can be expanded with 8 land phone line boards and allows to receive information from the control panel PSTN communicator. More technical information can be found by clicking on the menu bar black box “CMS equipment”.
Features
Features | PAS808M | PAS816 | PAS832 |
Alarm system concept | Wired modular system | Wired modular system | Wired modular system |
On-board wired zones | 8 | 8/16 (doubling) | 8/16 (doubling) |
2-wire smoke detector input | – | – | – |
On-board wireless zones | – | – | – |
Maximum zones in system | 8 | 16 | 32 |
On-board PGM | 3 | 3 | 3 |
Maximum PGM in system | 8 | 16 | 16 |
User + installer codes | 5+1 | 31+1 | 31+1 |
Duress code | X1, X2, X3, X4 (when X4 = X4 + 1) | ||
Defaulting user code | Yes | Yes | Yes |
Key switch zone | – | Yes | Yes |
Partitions | 4 | 4 | 4 |
“Shared” partition (common area) | – | Yes | Yes |
System timers | – | 16 | 16 |
Maximum keypads/modules in system | 7 | 15 | 15 |
Event log buffer | 512 | 512 | 512 |
PSTN communicator | In-built | In-built | In-built |
In-built interface for backup communicator | TTL Serial | TTL Serial | TTL Serial |
Data bus protocol | KRBUS | KRBUS | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 4 | 4 | 4 |
Maximum phone numbers for personal dialing | Up to 4 | Up to 4 | Up to 4 |
Maximum phone numbers for CMS reporting | Up to 4 | Up to 4 | Up to 4 |
Reporting protocol | Contact ID | Contact ID, 4×2 | Contact ID, 4×2 |
Voice guide for system control over PSTN | – | PAS816 V3 only | PAS832 V3 only |
Voice guide for system programming over PSTN | – | PAS816 V3 only | PAS816 V3 only |
“Roller” detector type | – | Yes | Yes |
“Vibration” detector type | Yes | Yes | Yes |
“Vibration” zone speed (sensitivity) | 0.01 – 0.25 sec. | 0.01 – 0.25 sec. | 0.01 – 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 – 2.5 sec. | 0.1 – 2.5 sec. | 0.1 – 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller | |
Arming mode | Away, Max Away, Night, Stay. | ||
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, interior night follower, perimeter, instant, PGM control;
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
||
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night | |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch | ||
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification | ||
Rated voltage of power supply (AC) | ~20 V | ~20 V | ~20 V |
Minimum AC voltage
(note: ~16 V input voltage lets control panel to generate max 0.7 A output current) |
~16 V | ~16 V | ~16 V |
Maximum AC voltage
(Note: higher than ~22 V voltage can damage control panel) |
~22 V | ~22 V | ~22 V |
Maximum long term output current of control panel
(I+AUX + I+BELL + I+PGM + battery charge): |
≤1.2 A | ≤1.5 A | ≤1.5 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA | 250 mA | 250 mA |
Maximum AC power consumption | 150 mA | 150 mA | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V | 12 V | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V | 13.9 V | 13.9 V |
Maximum current out of +AUX | +0.8 A | +1 A | +1 A |
Maximum current out of +BELL | +0.8 A | +2 A | +2 A |
Maximum current into -PGM | -0.05 A | -0.05 A | -0.05 A |
Maximum current out of +PGM | +0.8 A | +0.9 A | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic | Electronic | Electronic |
Battery charge, +BELL, +AUX current measurement | – | Yes | Yes |
Failed (waste) backup battery disconnection | – | Yes | Yes |
Maximum battery charging current | +0.4 A | +0.4 A | +0.4 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A | 3.15 A | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V | 9.5 V | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 | +EN50131, Grade2 | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 | 145 x 77 | 145 x 77 |
Environmental compliance | ROHS | ROHS | ROHS |
Operating temperature | -10oC up to +50oC | ||
Production status | In production | V2 discontinued,
V3 in production |
V2 discontinued,
V3 in production |
Latest firmware version | v0.03 | V2: |